Initial conditions of the hydraulic circuit for pressure and flow rate values as well as the four valve states. The initial flow rate in and out of compliance vessels is zero.

p [mmHg] q [mL s−1] D
lv 5.75 0.00 0.00
sa 83.45 5.68
sp 83.11 80.87
sv 3.29 70.95
ra 2.49 17.39 1.00
rv 2.44 0.00 0.00
pa 11.01 6.60
pp 10.86 55.38
pv 5.91 28.61
la 5.75 0.86 1.00