Skip to main content
. 2022 Oct 28;21:225. doi: 10.1186/s12934-022-01945-8

Fig. 3.

Fig. 3

Dissolved oxygen measurement in bioreactors throughout cultivation on propionate. Dissolved oxygen as expressed as percentage of content measured at 100% air at 0.1 L/min at 30 ºC using 300 RPM and 0% air. Arrows indicate at which time new propionate was injected to an end concentration of 10 mM. Samples for biomass, HPLC and B12 quantification were taken directly prior to each new propionate injection