Table 2.
Analysis of artificial intelligence algorithm calculated full length small bowel capsule endoscopy (N = 85).
| Variables | SBCE after colonoscopy (n = 50) | SBCE alone (n = 35) | p |
|---|---|---|---|
| Mean number of images in SBCE (SD) | 12,976.6 ± 7240.3 | 10,771.9 ± 5389.3 | 0.130 |
| AI calculated Cleanliness score (SD) | 3.970 ± 0.603 | 3.937 ± 0.428 | 0.785 |
| Cases of adequate cleansing | 43 (86.0%) | 32 (91.4%) | 0.445 |
| Cases of good cleansing | 27 (54.0%) | 17 (48.6%) | 0.622 |
SBCE small bowel capsule endoscopy, AI artificial intelligence, SD standard deviation.