Skip to main content
. 2022 Oct 6;7:285–316. doi: 10.1016/j.cnp.2022.09.003

Fig. 6.

Fig. 6

A: Back-averaging of a focal cortical transient preceding averaged left arm myoclonus electromyographic (EMG) discharges in a patient with cortical myoclonus. B: Enlarged cortical somatosensory-evoked potentials (SEP) from the same patient. Note the similarity of the P25-N33 wave dipole in both A and B. In both A and B, there is a positive wave in the CP4 electrode with a simultaneous FC4 negative wave. Averaged ear reference was used.