Table 2. Vibrational Frequencies for gauche-Ethanola.

mode scl-harm (ref (77))b scl-harm (ref (76))c MM (11 modes) MM (15 modes) AS SCIVR expt (ref (77))
7(CO–str) 1063 1064 **** 1085 1060 1066
8(CH2–rck) 1119 1129 **** 1124 1115 1117
9(CH2–twst) 1259 1256 **** 1259 1247 1249
10(COH–bnd) 1345 1348 **** 1337 1332 1342
11(CH2–wag) 1373 1376 1370 1370 1369 1373
12(CH3–sdef) 1396 1391 1393 1393 1386 1394 (1430)
13(CH3–adef′) 1461 1464 1448 1447 1448 1460
14(CH3–adef″) 1466 1467 1454 1454 1451 1465 (1460)
15(CH2–sdef) 1490 1489 1480 1480 1475 1493 (1460)
16(CH2–sstr) 2886 2874 2867d 2880d 2885 2912
17(CH3–sstr) 2912 2924 2874d 2923d 2909 2936
18(CH2–astr) 2978 2965 2927d 2950d 2957 2972
19(CH3–astr′) 2996 2990 2958d 2979d 2977 2987
20(CH3–astr″) 3015 3010 2976d 2978d 2985 2994
21(OH–str) 3579 3662 3659 3653 3655 3662
MAE 13 8 22 12 10  
a

Harmonic, MULTIMODE (4MR), AS SCIVR, and experimental IR gas values. Experimental values in parentheses refer to the Raman experiment. MAE is the mean absolute error with respect to the closest experimental frequency.

b

Scaled harmonic at MP2/6-31G(d) level. Scaling factors: 1.0 for heavy atom bend; 0.88 for CH stretches (str) and deformations (def); 0.90 for all other modes.

c

Scaled harmonic at DFT/B97-3c level. Scaling factor 0.979.

d

These states are mixed ones. See text and Table 4 for details. In the fourth column, the values 2950 for mode 18 and 2979 for mode 19 were employed in the MAE calculation.