Skip to main content
. 2022 Oct 18;13:1003659. doi: 10.3389/fpls.2022.1003659

Table 3.

The wind speed by the thermal anemometer and the calibrated measurement system.

Air Volume (m3·h-1) Wind Speed by the Proposed Measurement System (m·s-1) Wind Speed by the Thermal Anemometer (m·s-1) Relative Error(%)
Fibre Tube 1(Z) Fibre Tube 2(Y) Fibre Tube 3(X) Fibre Tube 1(Z) Fibre Tube 2(Y) Fibre Tube 3(X) Fibre Tube 1(Z) Fibre Tube 2(Y) Fibre Tube 3(X)
1869 3.075 -1.970 -1.712 2.828 2.150 1.782 8.751 8.370 3.901
2386 3.865 -2.827 -2.181 4.097 2.748 2.285 5.655 2.886 4.547
3534 5.820 -4.532 -3.381 5.963 4.528 3.153 2.405 0.084 7.235
4260 6.852 -5.535 -3.743 6.493 5.502 4.169 5.527 0.606 10.211
5191 8.286 -6.702 -4.720 8.479 6.671 4.826 2.279 0.458 2.203
6134 9.804 -7.789 -5.148 9.775 7.774 5.495 0.298 0.193 6.319
7448 11.419 -9.929 -5.154 11.649 10.324 5.256 1.978 3.829 1.933
8399 12.938 -10.817 -6.416 12.838 10.616 6.412 0.776 1.893 0.062
Average Relative Error (%) 3.458 2.290 4.551