Table 1.
Different small extracellular vesicle purification and isolation methods applied in bovine colostrum
Sample1 | Purification kit | RNA isolation kit | RNA concentration2 (ng/μL) | miRNA library quality check3 |
---|---|---|---|---|
1 | Plasma/Serum Exosome Purification Kit (Norgen Biotek Corp.) | Exosome RNA Isolation Kit (Norgen Biotek Corp.) | 18.05 | Passed |
2 | miRCURY Exosome Cell/Urine/CSF Kit (Qiagen) | Exosome RNA Isolation Kit (Norgen Biotek Corp.) | Failed | Failed |
3 | miRCURY Exosome Cell/Urine/CSF Kit (Qiagen) | miRNeasy Mini Kit (Qiagen) | 45.46 | Passed |
Three colostrum samples were collected from 3 dairy cows at the Dairy Research and Technology Centre (University of Alberta, Edmonton, Canada). Each colostrum sample was subjected to one combination of purification and RNA isolation kits.
The RNA concentration was measured using a Qubit 3.0 Fluorometer (Invitrogen) using 1 μL of RNA (1–1.5 mL of samples).
Quality check was done by analyzing 1 μL of the miRNA Sequencing Library on a 2200 TapeStation System (Agilent Technologies) using a High Sensitivity DNA chip according to the manufacturer's instructions.