Skip to main content
. 2022 Oct 19;9:1016255. doi: 10.3389/fcvm.2022.1016255

TABLE 3.

The one-stage hybrid procedure.

Hybrid procedure N = 30
LITA-LAD 30 (100%)
Ticagrelor (loading dose) 29 (96.6%)
Clopidogrel (loading dose) 1 (3.3%)
Acetylsalicylic acid 100%
PCI ¿ 1 artery 4 (13.3%)
PCI lesion type (34 lesions treated):
LCx/OM 19
IM 1
RCA 14
A n (%) 10 (29.4%)
B1 11 (32.3%)
B2 10 (29.4%)
C 3 (8.9%)
EACAB lesion type (30 lesions treated):
A n (%) 2 (6%)
B1 4 (14%)
B2 6 (20%)
C 18 (60%)
EES (Xience, Promus, Synergy) 30 (88.2%)
ZES (Resolute) 4 (11.8%)
Median number of implanted DES 1.0 (1.0–2.0)
Radiation dose (mGy) 655.0 (442.7–1047.5)
Fluoroscopy time (min) 9.7 (7.9–14.2)
Contrast dose (ml) 150.0 (150.0–200.0)

Data are presented as number (percentage) and mean ± standard deviation. DES, drug eluting stent; LITA-LAD, left internal mammary artery–left anterior descending artery bypass graft; PCI, percutaneous coronary intervention.