Skip to main content
. 2022 Mar 1;2(2):170–179. doi: 10.1016/j.jacasi.2021.11.015

Table 2.

Angiographic and Procedural Characteristics

Shellac + Vitamin E–Based DCB (n = 39) Iopromide-Based DCB (n = 39)
Multivessel disease 11 (28.2) 10 (25.6)
Lesion type, B2/C 16 (41.0) 21 (53.9)
Target vessel location
 Left anterior descending artery 18 (46.2) 19 (48.7)
 Left circumflex artery 10 (25.6) 9 (23.1)
 Right coronary artery 11 (28.2) 11 (28.2)
Mehran type
 I 19 (48.7) 17 (43.6)
 II 16 (41.0) 16 (41.0)
 III 4 (10.3) 5 (12.8)
 IV 0 1 (2.6)
TIMI flow grade 3 before procedure 39 (100.0) 39 (100.0)
Number of study balloons 1.0 ± 0.2 (40) 1.1 ± 0.3 (42)
Study balloon diameter, mm 3.0 ± 0.4 3.0 ± 0.4
Study balloon length, mm 24.6 ± 5.1 27.2 ± 7.0
Maximum study balloon pressure, atm 10.3 ± 2.7 9.8 ± 3.0
Study balloon inflation time, s 54.6 ± 12.5 53.9 ± 12.3
Delivery time to target lesion, s 43.8 ± 39.1 42.5 ± 33.2
TIMI flow grade 3 at end of procedure 39 (100.0) 39 (100.0)
Bailout strategy 0 0

Values are n (%), mean ± SD (n), or mean ± SD.

DCB = drug-coated balloon, TIMI = Thrombolysis In Myocardial Infarction.