Skip to main content
. Author manuscript; available in PMC: 2022 Nov 3.
Published in final edited form as: J Innov Opt Health Sci. 2020 Jan;13(1):1930013. doi: 10.1142/s1793545819300131

Table I.

Maximum sensitivity values and spatial coordinates of maximum sensitivity for intensity and phase measurements in the single-distance (SD) and dual-slope (DS) arrangements reported in Figs. 113 (LIN: linear; RHO: rhomboid; QDL: quadrilateral; IRR: irregular; RCT: rectangle; SQR: square; TPZ: trapezoid). The size of the optical inhomogeneity is 10×10×2 mm3.

Intensity Phase
Mode Shape-Figure Distances (mm) Maximum Sensitivity x (mm) y (mm) z (mm) Maximum Sensitivity x (mm) y (mm) z (mm)
SD Fig. 1 25 0.069 ±9.0 0 2.0 0.033 ±7.5 0 7.5
Fig. 2 35 0.046 ±14.0 0 2.0 0.021 ±14.5 0 7.5
DS LIN - Fig. 3 25,35 0.105 0 0 3.5 0.043 0 0 9.5
LIN - Fig. 4 20,30,40 0.107 −0.5 0 3.5 0.044 −1.0 0 9.5
RHO - Fig. 5 25,35 0.075 0 0 4.0 0.038 0 0 10.0
RHO - Fig.6 25,35 0.053 ±3.0 ±10.0 4.5 0.027 ±1.0 ±10.0 11.0
QDL - Fig.7 20,30,40 0.084 −2.0 1.5 6.0 0.041 −2.5 2.0 12.0
IRR - Fig.8 20,30,40 0.059 6.0 −5.5 4.0 0.030 3.0 −4.5 10.0
RCT - Fig.9 30,40 0.073 0 0 7.0 0.037 0 0 13.5
RCT - Fig.10 20,40 0.041 0 0 7.0 0.024 0 0 13.0
RCT - Fig.11 25,35 0.048 ±8.5 ±13.0 5.0 0.026 0 ±12.5 12.0
SQR - Fig.12 25,35 0.079 0 0 6.5 0.040 0 0 12.5
TPZ - Fig.13 25,35 0.102 0 5.0 4.0 0.043 0 4.5 10.5