Skip to main content
. Author manuscript; available in PMC: 2023 Nov 1.
Published in final edited form as: South Med J. 2022 Nov;115(11):818–823. doi: 10.14423/SMJ.0000000000001471

Table 3.

Relationship between evaluation components for stillbirths and hospital volume using χ2 tests, Arkansas, 2015–2020 (N = 1108)

Component Low volume, n (%) High volume, n (%) volume P A
<0.0001a
0 77 (19.1) 76 (13.9) 0.031
1 33 (8.2) 102 (18.7) <0.0001
2 190 (47.2) 219 (40.0) 0.029
3 92 (22.8) 135 (24.7) 0.508
4 11 (2.7) 15 (2.7) 0.991
≥3 0.521
 No 300 (74.4) 397 (72.6)
 Yes 103 (25.6) 150 (27.4)

High-volume hospitals were defined as those with >1000 deliveries; 158 observations had missing hospital volume information.

a

Denotes overall χ2 test.

A