Skip to main content
. 2022 Nov 5;9:41. doi: 10.1186/s40662-022-00314-1

Table 2.

Comparison of the classification performance on private anterior segment optical coherence tomography (AS-OCT) video datasets and image datasets

AUC (95% CI) Sensitivity Specificity Accuracy Precision Recall F1 Score Kappa
Casia dataset
 Images 0.766 (0.610–0.923) 0.790 0.750 0.771 0.771 0.771 0.771 0.539
 Original videos 0.820 (0.680–0.961) 0.833 0.765 0.800 0.801 0.800 0.800 0.599
 Aligned videos 0.905 (0.802–1.000) 0.947 0.690 0.829 0.844 0.829 0.824 0.648
Zeiss dataset
 Images 0.767 (0.620–0.914) 0.750 0.933 0.821 0.852 0.821 0.823 0.643
 Original videos 0.837 (0.713–0.961) 0.826 0.813 0.821 0.823 0.821 0.821 0.633
 Aligned videos 0.919 (0.831–1.000) 0.913 0.933 0.921 0.923 0.921 0.921 0.837

AUC = area under the receiver operating characteristic curve; CI = confidence interval

The bold numbers indicate optimal results