Skip to main content
. 2022 Nov 4;106(23):7737–7750. doi: 10.1007/s00253-022-12252-y

Table 1.

Applications of ACP in sewage and waste management

Waste and sewage disposal
Treatment target ACP generator Treatment Reference
Exposure distance (mm) Gas Time (min) Input power (W) Voltage (kV)
Municipal waste treatment Mini glide-arc 15 Air 5, 15, and 45 - 3.8 (Pawłat et al. 2021)
Industrial waste salt treatment DBD - Air and O2 0 ~ 25 - 12 ~ 16 (Wang et al. 2021)
Olive mill wastewater treatment Plasma jet - - 15 and 30 3500 0.2 (Ibrahimoglu and Yilmazoglu 2018)
Textile wastewater treatment DBD - O2 45 and 90 - - (Tecer et al. 2020)
Azo dye treatment DBD - Air, N2 and O2 1 ~ 15 - 20 (Iervolino et al. 2020)
Dye wastewater treatment Plasma jet 6 Air, N2, Ar, and O2 10 - 3 (Pandiyaraj et al. 2021)
Pesticide degradation DBD 37 Air 1 ~ 5 - 70 ~ 90 (Moutiq et al. 2020)
Sugarcane bagasse hydrolysate Plasma jet 10 Air 25 200 - (Lin et al. 2020)
Pineapple peel waste Plasma jet 10 Air and Ar 60 80–600 - (Santoso et al. 2021)