Skip to main content
. Author manuscript; available in PMC: 2024 Jan 1.
Published in final edited form as: J Trauma Acute Care Surg. 2022 May 12;94(1):125–132. doi: 10.1097/TA.0000000000003684

Table 3.

Imaging variables included in models for splenectomy and the composite outcome

Imaging Finding Odds Ratio 95% CI p-value
Splenectomy
 Active bleed, mL 6.592 1.567 – 27.726 0.010
 Pseudoaneurysm, mL 1.262 0.973 – 1.636 0.079
 Lactate, mmol/L 1.145 0.976 - 1.344 0.096
 Hemoperitoneum, mL 1.002 1.001 - 1.003 <0.001
Composite Outcome
 Pseudoaneurysm, mL 290.961 7.584 – 11162.3 0.002
 Splenic laceration, mL 1.040 1.018 – 1.068 0.005
 Hemoperitoneum, mL 1.001 1.000 – 1.003 0.011

Bolded p-values are statistically significant at a significance level of 5% (p<0.05) for testing the null hypothesis of odds ratio = 1.