Table 2.
Summary data from chemical analysis of filter papers and assessment of deviation from target dose per treatment. 5 filter papers (Whatman No.1) measuring 5 cm x 5 cm were fixed at 5 positions per huts, sprayed, left to dry and shipped within 2 weeks after IRS application to CEMAS for chemical analysis
Wall substrate | Control | VECTRON™ T500 (100 mg/m2) | Actellic® 300CS (1000 mg/m2) | |||||
---|---|---|---|---|---|---|---|---|
Cement | Mud | Cement | Mud | Cement | Mud | |||
Replicate 1 | Replicate 2 | Replicate 1 | Replicate 2 | |||||
Target dose (mg/m2) | N/A | 100 | 100 | 100 | 100 | 1000 | 1000 | |
Average (mg/m2) | – | – | 61 | 63 | 64 | 51 | 786 | 890 |
95% CI | – | – | 44–78 | 51–75 | 40–88 | 33–69 | 534–1038 | 697–1083 |
Deviation from target dose (%) | N/A | N/A | − 39 | − 37 | − 36 | − 49 | − 21 | − 11 |