Skip to main content
. 1999 Jun;67(6):2884–2890. doi: 10.1128/iai.67.6.2884-2890.1999

TABLE 3.

Fold increases in CTB-specific IgA and IgG responses in serum, BAL fluid, and urine after oral vaccination

Isotype Sample Response frequency (no. of responders/ total no.)a Geometric mean fold increaseb for:
P for all subjectsc
All subjects Responders
IgA Serum 4/6 8.6 13.2 0.01
BAL fluid 2/6 1.6 3.5 0.2
Urine 2/6 2.5 9.4 0.1
IgG Serum 4/6 3.8 8.0 0.08
BAL fluid 3/6 3.0 9.2 0.1
Urine 3/6 3.0 8.6 0.09
a

Responders were defined as having a greater than twofold increase in titer. 

b

The fold increases for all samples except serum are calculated from the titers adjusted for the total Ig content in the sample. 

c

Statistical significance of titer increases obtained by using the paired Student t test.