Colonoscopy quality metrics following a positive mt-sDNA test, following a positive FIT test, or colonoscopy alone (average-risk patientsa).

Colonoscopy preparation quality
Colonoscopy after positive mt-sDNA test Colonoscopy after positive FIT test Colonoscopy only Overall P P value (mt-sDNA vs. FIT) P value (mt-sDNA vs. colo only) P value (FIT vs. colo only)
Total number of patients (N = 240) (N = 194) (N = 26,221)
Colonoscopy preparation quality N % N % N %
 Excellent or good 191 91.4 170 91.4 22,347 94.5 0.0280 1.0000 0.0648 0.0736
 Fair 18 8.6 16 8.6 1,296 5.5
 Missing 31 8 2,578
Withdrawal time and recommended rescreening interval among patients with normal exams with no findings
Colonoscopy after positive mt-sDNA test Colonoscopy after positive FIT test Colonoscopy only Overall P P value (mt-sDNA vs. FIT) P value (mt-sDNA vs. colo only) P value (FIT vs. colo only)
Total number of patients (N = 55) (N = 68) (N = 12,813)
Withdrawal timeb N % N % N %
 Less than 9 minutes 20 48.8 27 51.9 4,705 47.5 0.8148 0.8358 0.8771 0.5787
 Greater than or equal to 9 minutes 21 51.2 25 48.1 5,191 52.5
 Missing 14 16 2,917
Recommended colonoscopy rescreening interval
N % N % N % 0.0129 0.5673 0.2419 0.0104
 Less than 10 years 5 14.7 10 21.3 910 9.3
 Greater than or equal to 10 years 29 85.3 37 78.7 8,871 90.7
 Missing 21 21 3,032

Abbreviation: colo, colonoscopy.

aAverage-risk definition: No prior personal history of polyps or colorectal cancer and no first degree family history of colorectal cancer.