Diagnostic efficiency of the GAD-7 with CIDI-GAD as a gold standard

Cut-off Sensitivity Specificity YI PPV (%) NPV (%) LR+ LR-
≥5 0.882 0.643 0.525 3.2 99.7 2.47 0.18
≥6 0.824 0.728 0.552 3.8 99.7 3.03 0.24
≥7 0.784 0.808 0.592 4.5 99.6 4.08 0.27
≥8 0.725 0.835 0.560 6.2 99.5 4.39 0.33
≥9 0.667 0.863 0.530 6.5 99.4 4.87 0.39
≥10 0.627 0.883 0.510 7.1 99.4 5.36 0.42

YI Youden Index, PPV Positive predictive value, NPV Negative predictive value, LR+ Positive likelihood ratio, LR- Negative likelihood ratio