Skip to main content
. 2022 Nov 11;101(45):e31775. doi: 10.1097/MD.0000000000031775

Table 3.

Intubation data of the C-MAC D-blade and McCoy laryngoscopes.

Group C Group M P
(n = 47) (n = 43)
VAS of facemask ventilation difficulty 3.06 ± 1.46 3.56 ± 2.03 .186
Cormack–Lehane grade .000
 1 17 (36.17%) 5 (11.63%)
 2 29 (61.71%) 23 (53.49%)
 3 1 (2.12%) 15 (34.88%)
POGO (%) 79.36 ± 13.42 53.49 ± 29.83 .000
Ease of laryngoscope insertion .101
 Ease 39 (82.98%) 32 (74.42%)
 Moderate 8 (17.02%) 7 (16.28%)
 Difficult 0 (0%) 4 (9.30%)
Ease of tube advancement .523
 Ease 29 (61.70%) 31 (72.09%)
 Moderate 12 (25.53%) 7 (16.28%)
 Difficult 6 (12.77%) 5 (11.63%)
Number of intubation attempt .570
 1 41 (87.23%) 40 (93.02%)
 2 5 (10.64%) 2 (4.65%)
 3 1 (2.13%) 1 (2.33%)
Intubation Difficulty Scale .030
 1 15 (31.91%) 5 (11.63%)
 2 26 (55.32%) 22 (51.16%)
 3 5 (10.64%) 13 (30.23%)
 4 0 (0%) 2 (4.65%)
 5 1 (2.13%) 1 (2.33%)
Malposition .716
 Yes 5 (10.64%) 3 (6.98%)
 No 42 (89.36%) 40 (93.02%)
DLT intubation time (sec) 35.85 ± 10.77 33.18 ± 11.97 .269
VAS of severity of sore throat 3.28 ± 1.75 3.51 ± 1.79 .531

Mean ± standard deviation or number of patients (%). Group C = C-MAC D-blade laryngoscope group, group M = McCoy laryngoscope group. DLT = double lumen intubation, POGO = percentage of glottis opening, VAS = visual analogue scale.