Author Strategy to reduce tremors Surgical metric Improved performance Speciality Evidence quality Year Country n
Roizenblatt et al. [23] Beta-blocker (tremor reducing), caffeine (tremor increasing) Simulator score Yes (beta-blocker) Ophthalmology II 2020 Brazil 15
Pointdujoir et al. [24] Beta-blocker (propranolol) Simulator score Yes Ophthalmology III 2011 America 18
Nakano et al. [14] Robotic surgical system Stability and accuracy Yes Ophthalmology IV 2009 Japan NS
Yang et al. [15] “Micron” handheld robotic micromanipulator Physiologic tremor filtration and RMS error Yes Ophthalmology IV 2015 America 1
Song et al. [16] Swept source optical coherence tomography-based “SMART” handheld tool Maintained tool tip offset distance Yes Ophthalmology IV 2012 America 2
Maclachlan et al. [17] Actively stabilized handheld tool Position error on several error metrics Yes Ophthalmology IV 2013 America 6
Gonenc et al. [25] “Micron” handheld robotic micromanipulator Magnitude of forces during membrane peeling of a phantom bandage and membrane on raw chicken egg Yes Ophthalmology IV 2012 America 1
Song et al. [18] Fibre-optic OCT sensor-guided SMART microforceps Targeted grasping and peeling performance Yes Ophthalmology IV 2013 America NS
Zhang et al. [19] Hand-held instrument with active tremor compensation Tip force applied while peeling inner shell membrane of chicken egg Yes Ophthalmology IV 2020 China 1
Gonenc et al. [26] Micron with force sensing Peeling force and peeling speed on phantom bandages and eggs Yes Ophthalmology IV 2014 America 1
Yang et al. [20] Micron with force sensing RMS error for holding-still and circle tracing in eye phantom and rubber target Yes Ophthalmology IV 2013 America 1
Okamura et al. [21] Freely movable arm rest (FMA) Arm fatigue, subjective tremor score, and suturing accuracy No Ophthalmology IV 2020 Japan 8

RMS root mean square, RMSE root-mean-square error, N novice, E expert, L longer time, S shorter time, A average, M maximum, MTS microvascular tremor scale, TTC time to completion, TLM transoral laser microsurgery, RVBS retinal vein bypass surgery, NS not specified