Table 1.
Case report form vs. video review.
No | Ventilation time* noted in case report form in seconds | Ventilation time* according to video review in seconds |
---|---|---|
1 | 1,345 | 2,100 |
2 | 57 | 60 |
3 | 112 | 189 |
4 | 44 | 52 |
5 | 40 | 55 |
6 | 895 | 2,171 |
7 | 95 | 120 |
8 | 1,250 | 1,412 |
9 | 131 | 169 |
10 | 90 | 92 |
11 | 650 | 1,007 |
12 | 387 | 2,560 |
13 | 330 | 490 |
14 | 76 | 87 |
15 | 112 | 110 |
16 | 121 | 100 |
17 | 65 | 85 |
18 | 80 | 68 |
19 | 57 | 102 |
20 | 245 | 284 |
21 | 80 | 117 |
22 | 54 | 87 |
23 | 128 | 125 |
24 | 108 | 118 |
25 | 131 | 136 |
26 | 150 | 263 |
27 | 308 | 376 |
28 | 324 | 402 |
29 | 690 | 726 |
30 | 113 | 197 |
31 | 18 | 19 |
32 | 369 | 2,254 |
33 | 1,086 | 1,370 |
34 | 250 | 287 |
35 | 800 | 888 |
36 | 83 | 121 |
37 | 396 | 2,266 |
38 | 291 | 592 |
39 | 109 | 168 |
40 | 118 | 195 |
41 | 194 | 261 |
42 | 105 | 162 |
43 | 101 | 192 |
44 | 48 | 54 |
45 | 798 | 983 |
46 | 46 | 57 |
47 | 707 | 886 |
48 | 39 | 56 |
Ventilation time is the time in seconds from the start of ventilation to the end when the resuscitation device is removed from the baby's mouth.