Table 4. Values relating to sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios and accuracy of magnetic resonance imaging, compared with arthroscopy (gold-standard), for each evaluator.

Subscapularis full-thickness tear Subscapularis tear (full-thickness + partial)
Mean 95% CI Mean 95% CI
Inferior Superior Inferior Superior
Shoulder surgeon (1st evaluation)
Sensitivity 39.3% 27.2% 52.1% 51.1% 43.2% 59.1%
Specificity 91.7% 87.5% 96.3% 82.0% 72.4% 92.3%
Positive predictive value 64.7% 49.2% 81.4% 86.6% 79.1% 94.3%
Negative predictive value 79.5% 73.1% 86.7% 42.4% 33.4% 51.7%
Accuracy 77.0% 71.2% 83.5% 60.5% 53.2% 67.3%
Shoulder surgeon (2nd evaluation)
Sensitivity 35.7% 23.2% 48.3% 59.0% 51.0% 67.1%
Specificity 94.4% 91.2% 98.5% 78.7% 68.3% 89.8%
Positive predictive value 71.4% 55.1% 88.4% 86.3% 79.7% 93.2%
Negative predictive value 79.1% 73.2% 85.2% 45.7% 36.6% 55.5%
Accuracy 78.0% 72.7% 84.4% 65.0% 58.3% 72.3%
MSK radiologist 1
Sensitivity 71.4% 60.1% 83.4% 83.5% 77.7% 90.0%
Specificity 85.4% 80.2% 91.1% 45.9% 33.4% 58.1%
Positive predictive value 65.6% 53.1% 77.2% 77.9% 71.6% 84.7%
Negative predictive value 88.5% 83.2% 94.7% 54.9% 41.1% 69.3%
Accuracy 81.5% 76.2% 87.7% 72.0% 66.3% 78.2%
MSK radiologist 2
Sensitivity 57.1% 44.2% 70.2% 87.1% 82.7% 93.3%
Specificity 86.1% 80.1% 92.1% 41.0% 29.5% 53.6%
Positive predictive value 61.5% 48.4% 75.3% 77.1% 70.2% 84.1%
Negative predictive value 83.8% 78.5% 90.2% 58.1% 43.7% 73.2%
Accuracy 78.0% 72.5% 84.1% 73.0% 67.3% 79.4%

CI = confidence interval; MSK = musculoskeletal.