Table 5.
Comparison of outputs of different studies for nanofibers with/without dopants.
| Sample | Force (N) | Area (m2) | Pressure (Pa) | Output voltage (V) | Sensitivity (V/KPa) | Current (nA) | Source |
|---|---|---|---|---|---|---|---|
| PVDF/no TiO2 | 5 | 0.006 | 833.33 | 7 | 8.4 | 104 | [9] |
| PVDF/no BTO | - | - | 7000 | - | - | 4.8 | [10] |
| PVDF/no G | 8 | 825 | 6600 | 4.5 | 0.68 | - | [11] |
| PVDF/no MoS2 | 7 | 1257.142 | 8800 | 2.5 | 0.28 | - | [12] |
| PVDF/TiO2 | 5 | 0.006 | 833.33 | 11.5 | 13.8 | 176 | [9] |
| PVDF/BTO | - | - | 7000 | - | - | 12.5 | [10] |
| PVDF/G | 8 | 825 | 6600 | 11 | 1.66 | - | [11] |
| PVDF/MoS2 | 7 | 1257.142 | 8800 | 14 | 1.59 | - | [12] |