Skip to main content
. 2022 Nov 7;10:948230. doi: 10.3389/fbioe.2022.948230

TABLE 3.

Results of acoustic profiles measured at different anatomical locations.

Anatomical locations Transverse sinus Transverse-sigmoid junction Lower curve of sigmoid sinus Jugular bulb Upper internal jugular vein
Position of virtual microphones (Node Numbers) 82,140 23,100 80,991 24,687 751
VIBRO Peak amplitude a (dB/dBA) 119.3/85.4 111.2/78.7 102.0/69.8 103.4/67.7 106.2/56.1
RMS amplitude a (dB/dBA) 82.0/74.1 75.4/67.4 67.5/59.4 64.4/56.2 48.6/56.1
Frequency at peak amplitude (HzdB/HzdBA) 20.2/264.8 20.2/20.2 20.2/264.8 20.2/264.8 20.2/264.8
HYDRO Peak amplitude a (dB/dBA) 74.3/35.8 76.3/33.7 76.5/29.5 80.0/30.0 77.7/27.7
RMS amplitude a (dB/dBA) 23.7/11.7 24.2/11.8 23.2/10.5 23.2/10.2 18.5/10.5
Frequency at peak amplitude b (HzdB/HzdBA) 20.2/39.1 20.2/58.1 20.2/39.10 20.2/20.2 20.2/20.2
a

indicates the amplitude of the observed frequency within 20–1,000 Hz. VIBRO and HYDRO indicates parameters of vibroacoustic and hydroacoustic noise.

b

HzdB/HzdBA indicates the frequency at peak amplitude (dB)/(dBA).