Hydrodynamic diameter, polydispersity index (PDI), radius of main peak and relative intensity of main peak of untreated and stressed samples of Comirnaty vaccine determined by DLS.

Sample Hydrodynamic radius [nm] PDI Radius of main peak [nm] Relative intensity of main peak [%]
Untreated 66 ± 9 Multimodal 36 ± 2 70 ± 6
30 °C 77 ± 16 Multimodal 37 ± 4 65 ± 7
50 °C 76 ± 12 Multimodal 35 ± 4 65 ± 9
80 °C 55 ± 8 Multimodal 47 ± 7 84 ± 6
Freeze-thawed 132 ± 3 0.38 ± 0.07** 139 ± 28 75 ± 13
Vortex 71 ± 7 Multimodal 49 ± 5 77 ± 10
**