Green Analytical Procedure Index (GAPI) parameters for the proposed method.
Categorya | Description |
---|---|
Sample preparation | |
Collection (1) | Off-line |
Preservation (2) | None |
Transport (3) | None |
Storage (4) | Normal condition |
Type of method: direct or indirect (5) | Direct |
Scale of extraction (6) | Micro-extraction |
Solvents/reagents used (7) | Green solvents/reagents used |
Additional treatments (8) | Simple treatments (clean up, solvent removal, etc.) |
Reagent and solvents | |
Amount (9) | <10 mL |
Health hazard (10) | AgNO3 = 3 Sod. borohydride = 3 |
Safety hazard (11) | AgNO3 = 0 Sod. borohydride = 1 |
Instrumentation | |
Energy (12) | ≤1.0 kW h per sample |
Occupational hazard (13) | Hermetic sealing of the analytical process |
Waste (14) | 1–10 mL |
Waste treatment (15) | No treatment |
Quantificationb | Yes |
The numbers between parentheses are the numbers in the GAPI pictogram (on the right).
The circle inside the central pentagram represent the quantification property of the method.