Table 2.

Summary of the top DRF found after the feature selection phase organized by clinical endpoint and reconstruction and pre-processing method. Asterisks were placed on the iCBCT and sCBCT reconstruction and pre-processing methods with the best performing AUC in their respective categories.

Clinical endpoint Reconstruction and pre-processing method N Selected features
Acute iCBCT SHARP VeryLow Llo 1 6 GLCM Correlation, GLCM Homogeneity, GLSZM GLN-VN, Global Skewness, NGTDM Coarseness-VN, Prostate Volume
Acute iCBCT SHARP VeryLow Uni 0 3 GLCM Correlation, NGTDM Coarseness-VN, Prostate Volume
Acute iCBCT STD Med Llo 1 4 GLCM Contrast, GLCM Dissimilarity, GLSZM LZHGE, Prostate Volume
Acute iCBCT STD Med Uni 0* 4 GLSZM LZHGE, NGTDM Coarseness-VN, NGTDM Strength, Prostate Volume
Acute sCBCT SHARP Llo 1 6 GLCM Energy, GLRLM LRHGE, GLSZM GLN-VN, Global Kurtosis, Global Skewness, NGTDM Busyness
Acute sCBCT SHARP Uni 0 5 GLRLM GLN-VN, GLSZM GLN, GLSZM GLN-VN, NGTDM Coarseness, Prostate Volume
Acute sCBCT STD Llo 1 4 GLSZM GLN, GLSZM GLN-VN, Global Kurtosis, Prostate Volume
Acute sCBCT STD Uni 0* 6 GLRLM GLN, GLRLM GLN-VN, GLSZM ZSN, GLSZM ZSV, Global Kurtosis, Prostate Volume
Sub-Acute iCBCT SHARP VeryLow Llo 1 3 GLCM Contrast, GLCM Correlation, NGTDM Contrast
Sub-Acute iCBCT SHARP VeryLow Uni 0 3 GLCM Correlation, GLRLM RLN, GLSZM ZSN
Sub-Acute iCBCT STD Med Llo 1* 6 GLCM Contrast, GLCM Correlation, GLCM Dissimilarity, GLSZM LZLGE, NGTDM Coarseness, NGTDM Strength
Sub-Acute iCBCT STD Med Uni 0 5 GLSZM GLN, GLSZM LZHGE, GLSZM LZLGE, GLSZM ZSV, NGTDM Coarseness
Sub-Acute sCBCT SHARP Llo 1 4 GLCM SumAverage, GLRLM LRHGE, GLSZM GLN, GLSZM LZHGE
Sub-Acute sCBCT SHARP Uni 0 5 GLCM Correlation, GLRLM GLV, GLSZM GLV, GLSZM ZSV, Global Skewness
Sub-Acute sCBCT STD Llo 1 7 GLCM Variance, GLRLM RLN, GLSZM GLN, GLSZM LZLGE, Global Kurtosis, NGTDM Contrast, NGTDM Strength
Sub-Acute sCBCT STD Uni 0* 4 GLRLM RLN, GLSZM ZSN, Global Skewness, NGTDM Coarseness-VN
∆IPSS iCBCT SHARP VeryLow Llo 1 6 GLRLM GLN, GLRLM LRLGE, GLRLM RLN, GLSZM ZSN, IPSS Baseline, NGTDM Contrast
∆IPSS iCBCT SHARP VeryLow Uni 0 4 GLRLM RLN, GLSZM SZE, IPSS Baseline, NGTDM Coarseness
∆IPSS iCBCT STD Med Llo 1 4 GLRLM RLN, GLRLM RLV, GLRLM SRE, IPSS Baseline
∆IPSS iCBCT STD Med Uni 0* 4 GLRLM RLN, GLSZM SZLGE, GLSZM ZP, IPSS Baseline
∆IPSS sCBCT SHARP Llo 1* 4 GLRLM GLN, GLRLM RLN, Global Variance, IPSS Baseline
∆IPSS sCBCT SHARP Uni 0 3 GLRLM RLN, IPSS Baseline, NGTDM Contrast
∆IPSS sCBCT STD Llo 1 6 GLCM Variance, GLRLM GLN, GLRLM RLN, GLSZM LZE, Global Variance, IPSS Baseline
∆IPSS sCBCT STD Uni 0 6 GLCM Correlation, GLRLM RLN, GLSZM GLN-VN, IPSS Baseline, NGTDM Coarseness, NGTDM Contrast