Skip to main content
. 2022 Nov 8;9(11):665. doi: 10.3390/bioengineering9110665

Table 5.

MLR, NLR and PLR coefficients for prediction of extraction efficiencies based on DESs physical properties (significant coefficients for p < 0.05 are marked bold).

MLR NLR PLR
Break point 52.9 ± 5.1
b 0 2489 ± 561.4 1.4 ± 0.9 1310.6 ± 157.1
−4315.7 ± 237.2
b1 (ρ) −292.3 ± 83.8 −17.9 ± 4.3 −2604.4 ± 188.9
−367.9 ± 22.5
b2 (η) 2 × 10−2 ± 1 × 10−3 −0.1 ± 3 × 10−2 2 × 10−2 ± 1 × 10−3
−46.9 ± 21.1
b3 (σ) −0.7 ± 0.5 −1 × 10−2 ± 3 × 10−3 5.2 ± 2.1
1.5 ± 0.6
b4 (nD) −1573.7 ± 371.3 20.7 ± 1.7 −7991.6 ± 255.6
3084.7 ± 154.1
b5 (a) −220.5 ± 97.3 −13.9 ± 4.1 694.9 ± 115.7
−317.5 ± 59.7
b6 (λ) 738.1 ± 18.4 16.6 ± 4.22 4789.4 ± 321.5
1455.2 ± 118.7
b7 (cp) −3.2 ± 1.2 −13.5 ± 3.9 217.2 ± 15.8
24.2 ± 3.8
R 2 0.62 0.73 0.97
R 2 adj 0.51 0.68 0.97
RMSE 5.89 4.47 1.45
F−value F (7,34) = 7.9 F (7,34) = 7.9 F (7,34) = 7.9
p−value p < 0.001 p < 0.001 p < 0.001