Table 2.
Summary of wearable EOG platforms.
Wearable Platforms |
Electrodes | Platforms | Refs. | |||
---|---|---|---|---|---|---|
Types | Materials | Counts | Size | Features | ||
Earplug | Foam | Silver | 2 | 2 × 2 × 1 mm3 | -Stable and comfy during sleep | [44,45] |
Foam | Conductive cloth | 2 | 2 × 2 × 1 mm2 | -Stable and comfy during sleep | [43] | |
Eyeglass | Gel | Ag/AgCl | 6 | 15 × 14 × 5 cm3 | -Lots of wires were attached | [37] |
Metal | Silver | 3 | 15 × 14 × 5 cm3 | -Real-time delivery of feedback in the form of an auditory | [32,33,117] | |
Metal | Ag/AgCl | 5 | 15 × 14 × 7 cm3, 150 g | -Constant pressure for electrodes | [34,116] | |
Foam | CNT/PDMS | 5 | 15 × 14 × 5 cm3 | -UV protection via sunglass lens | [5] | |
Foam | Ni/Cu | 5 | 14 × 12 × 7 cm3 | -Absorbing the motion force via Foam and platform | [38] | |
Facemask | Fiber | Silver/Polyamide | 3 | 14 × 7 × 2 cm3 | -The wires are embedded in the eye mask platform | [40] |
Metal | Silver/Carbon | 8 | 20 × 15 cm2 | -Tattoo-based platform-Stable and comfy | [41] | |
Fiber | Graphene | 5 | 15 × 7 × 2 cm3 | -High degree of flexibility and elasticity | [42] | |
Headband | Gel | Ag/AgCl | 4 | 15 × 7 cm2 | -Waveforms were well measured on the headband platform | [51] |
Metal | Ag/AgCl | 4 | 15 × 7 cm2 | -Reduction in the total cost by using disposable Ag/AgCl medical electrodes | [55] | |
Fiber | Graphene | 3 | 15 × 7 cm2 | -Long-term EOG monitoring applications | [21,57,96] | |
Fiber | Silver | 5 | 15 × 7 cm2 | -Reusable and easy-to-use electrodes are integrated into the cap. | [89] | |
Fiber | silver-plated and nylon | 3 | 15 × 7 cm2 | -Long-term EOG monitoring applications | [58] |