Skip to main content
. 2022 Nov 3;12(11):2679. doi: 10.3390/diagnostics12112679

Table 1.

Intra-rater reliability of the manual measurements; rater 2a vs rater 2b; preoperative n = 95, postoperative n = 105.

Intra-Rater Reliability (Rater 2a vs. Rater 2b)
Statistical Method mMPTA [°] mLDFA [°] mFAmTA [°] mLDTA [°] FSAmTA [°]
Preoperative ICC
(95% CI)
0.97
(0.95–0.98)
0.95
(0.93–0.97)
1.0
(1.0–1.0)
0.97
(0.96–0.98)
1.0
(1.0–1.0)
Mean error
(95% CI)
−0.07
(−0.27–0.13)
−0.02
(−0.22–0.19)
−0.01
(−0.06–0.05)
−0.13
(−0.37–0.12)
−0.05
(−0.14–0.03)
SD 0.97 1.0 0.26 1.19 0.4
RMSE 0.97 1.0 0.26 1.2 0.41
Pearson
correlation r
(p-value)
0.97
(<0.001)
0.95
(<0.001)
1.0
(<0.001)
0.97
(<0.001)
1.0
(<0.001)
Postoperative ICC
(95% CI)
0.96
(0.94–0.97)
0.97
(0.95–0.98)
1.0
(0.99–1.0)
0.96
(0.94–0.97)
0.99
(0.99–1.0)
Mean error
(95% CI)
0.0
(−0.1–0.09)
−0.05
(−0.2–0.1)
−0.01
(−0.07–0.04)
0.15
(−0.1–0.4)
0.01
(−0.06–0.08)
SD 0.48 0.77 0.28 1.29 0.37
RMSE 0.48 0.77 0.28 1.3 0.37
Pearson
correlation r
(p-value)
0.96
(<0.001)
0.97
(<0.001)
1.0
(<0.001)
0.96
(<0.001)
1.0
(<0.001)

ICC, intraclass correlation coefficient; CI, confidence interval; SD, standard deviation; RMSE, root mean square error.