Water uptake and proton conductivity of membranes. Adapted with permission from [76]. Copyright 2018, Elsevier.

Sample Water Uptake a
(%)
Proton Conductivity b (mS cm−1)
20% RH 80% RH
Nafion/sMWCNT (0.125 wt.%) 17.2 8.0 180
Nafion/sMWCNT (0.25 wt.%) 29.3 23.0 198
Nafion/sMWCNT (0.5 wt.%) 16.4 6.0 165
Recast Nafion 15.8 2.0 160