Table 2:
Free Energy Estimator Accuracy Relative to Reference Calculation
| c = 15.5 | c = 5.5 | |||||
|---|---|---|---|---|---|---|
| 1 kcal/mol barrier | No barrier | |||||
| Estimatora | cRMSE | MUE | R | cRMSE | MUE | R |
| T4L 3 Site System | ||||||
| Independent site | 0.41 | 0.73 | 0.972 | 0.43 | 0.94 | 0.971 |
| Potts model | 0.22 | 0.38 | 0.994 | 0.07 | 0.07 | 0.999 |
| Histogram-based | 0.23 | 0.36 | 0.994 | 0.07 | 0.08 | 0.999 |
| T4L 4 Site System | ||||||
| Independent site | 0.53 | 0.59 | 0.923 | 0.70 | 0.64 | 0.896 |
| Potts model | 0.48 | 0.41 | 0.922 | 0.44 | 0.43 | 0.948 |
| Histogram-based | 0.51 | 0.41 | 0.922 | 0.46 | 0.51 | 0.940 |
| T4L 5 Site System | ||||||
| Independent site | 0.68 | 0.88 | 0.892 | 0.92 | 1.44 | 0.789 |
| Potts model | 0.59 | 0.46 | 0.924 | 0.55 | 0.57 | 0.933 |
| Histogram-based | - | - | - | - | - | - |
| HIV-RT Inhibitors | ||||||
| Independent site | 0.48 | 0.97 | 0.974 | 0.50 | 1.02 | 0.973 |
| Potts model | 0.30 | 0.26 | 0.990 | 0.37 | 0.29 | 0.985 |
| Histogram-based | 0.31 | 0.25 | 0.989 | - | - | - |
| p38 Inhibitors | ||||||
| Independent site | 0.36 | 0.87 | 0.958 | 0.45 | 0.90 | 0.945 |
| Potts model | 0.42 | 0.59 | 0.952 | 0.52 | 0.61 | 0.935 |
| Histogram-based | 0.46 | 0.54 | 0.942 | - | - | - |
The best estimator for each system and metric is highlighted in bold. If insufficient sampling is available to estimate free energies for all alchemical states with a particular estimator, a dash is displayed.