Table 1.

Tau coefficient and p-value from Kendall correlation between each metric and RLN and SLN activation. Range and standard deviation also included. Asterisk indicates statistically significant findings.

F0 H1-H2 CPP Closing Quotient (CQ) Open Quotient (OQ) Glottal Volume, normalized (mm)
Tau coefficient for RLN (p-value)
0.674 (<0.0001)* 0.699 (<0.0001)* 0.741 (<0.0001)* −0.323 (0.560) −0.098 (0.219) −0.407 (0.288)
Tau coefficient for SLN (p-value) 0.417 (<0.0001)* 0.383 (<0.0001)* 0.225 (0.015)* 0.797 (0.004)* 0.623 (0.030)* 0.681 (0.015)*
Range (Standard Deviation)