. 2022 Nov 21;2022:6855775. doi: 10.1155/2022/6855775

Table 2.

Effect of electroacupuncture at the right TE3 on peak latency and interpeak amplitude of late latency response (LLR) recordings.

Baseline D3 D5 D8
Peak latency (ms)
P0
 EA 15.933 ± 1.808 19.889 ± 1.372 18.133 ± 0.970 15.600 ± 0.781
 Control 14.867 ± 0.825 13.689 ± 1.006 14.556 ± 1.633 15.644 ± 0.953
Na
 EA 23.022 ± 2.244 25.511 ± 1.550 23.156 ± 1.076 22.311 ± 1.439
 Control 20.444 ± 1.104 19.889 ± 0.996 20.667 ± 1.225 21.978 ± 1.129
Pa
 EA 38.667 ± 3.953 37.578 ± 3.176 35.044 ± 4.742 33.533 ± 3.816
 Control 37.533 ± 2.934 33.533 ± 3.732 37.378 ± 4.356 38.844 ± 3.948
Nb
 EA 56.111 ± 3.056 51.978 ± 5.424 45.378 ± 5.995∗∗ 42.711 ± 2.739∗∗∗
 Control 55.311 ± 4.975 52.311 ± 4.042 53.222 ± 7.502 50.356 ± 7.124
Pb
 EA 64.711 ± 1.806 60.422 ± 6.579 56.400 ± 5.334 50.578 ± 4.065∗∗∗∗
 Control 69.556 ± 5.895 61.556 ± 5.270 62.889 ± 6.410 57.300 ± 7.161

Peak latency shift (ms)
P0
 EA 0.000 ± 0.000 3.956 ± 2.975## 2.200 ± 1.889# −0.333 ± 1.949
 Control 0.000 ± 0.000 −1.178 ± 1.358 −0.311 ± 1.078 0.778 ± 1.146
Na
 EA 0.000 ± 0.000 2.489 ± 2.965 0.133 ± 2.912 −0.711 ± 1.895
 Control 0.000 ± 0.000 −0.556 ± 1.374 0.222 ± 1.185 1.533 ± 1.685
Pa
 EA 0.000 ± 0.000 −1.089 ± 6.018 −3.622 ± 6.686 −5.133 ± 6.993
 Control 0.000 ± 0.000 −4.000 ± 4.496 −0.156 ± 6.300 1.311 ± 4.390
Nb
 EA 0.000 ± 0.000 −4.133 ± 4.862 −10.733 ± 6.357 −13.400 ± 4.688
 Control 0.000 ± 0.000 −3.000 ± 6.736 −2.089 ± 9.983 −4.956 ± 10.780
Pb
 EA 0.000 ± 0.000 −4.289 ± 6.479 −8.311 ± 5.969 −14.133 ± 4.598
 Control 0.000 ± 0.000 −8.000 ± 8.367 −6.667 ± 8.345 −13.300 ± 10.613

Interpeak amplitude (uV)
P0–Na
 EA 0.779 ± 0.302 0.744 ± 0.683 1.252 ± 0.569 0.815 ± 0.596
 Control 0.829 ± 0.098 0.508 ± 0.045 1.285 ± 0.221 0.708 ± 0.393
Na–Pa
 EA 1.765 ± 0.312 2.348 ± 0.680 2.460 ± 0.440 1.408 ± 0.409
 Control 1.367 ± 0.081 1.145 ± 0.257 1.310 ± 0.793 1.135 ± 0.274
Pa–Nb
 EA 0.733 ± 0.259 0.776 ± 0.225 1.076 ± 0.242 1.345 ± 0.947
 Control 0.463 ± 0.133 0.365 ± 0.239 0.558 ± 0.328 0.700 ± 0.456
Nb–Pb
 EA 0.959 ± 0.175 1.074 ± 0.336 1.580 ± 0.648 1.235 ± 0.803
 Control 0.968 ± 0.275 0.883 ± 0.205 0.790 ± 0.396 1.148 ± 0.287

Data are presented as mean ± standard deviation (SD); EA: electroacupuncture group; control: control group; D5: fifth day after baseline recordings; D8: eighth day after baseline recordings; P0: wave P0 of LLR; Na: wave Na of LLR; Pa: wave Pa of LLR; Nb: wave Nb of LLR; Pb: wave Pb of LLR; shift: the value of D3, D5, or D8 minus the baseline value; p < 0.05, ∗∗p < 0.01, ∗∗∗p < 0.001 compared with baseline; ∗∗∗∗p < 0.0001 compared with baseline; #p < 0.05, ##p < 0.01 compared with control.