Table 5.

Accuracies of single labelling and multi-labelling for STEMI and 12 heart rhythms of the LSTM model

ECG diagnoses Accuracy of single labelling (n = 260) Accuracy of multi-labelling (n = 99)
Acute STEMI 0.9962 (n = 8) 0.9375 (n = 15)
AFIB 0.9577 (n = 46) 0.9792 (n = 2)
AFL 0.9577 (n = 18) 1.0000 (n = 0)a
APB 0.9846 (n = 17) 0.9167 (n = 16)
BIGEMINY 0.9962 (n = 21) 1.0000 (n = 4)
CHB 0.9885 (n = 8) 0.9792 (n = 2)
EAR 0.9462 (n = 17) 0.9375 (n = 5)
FRAV 0.9808 (n = 15) 0.8125 (n = 20)
NSR 0.9462 (n = 32) 1.0000 (n = 0)a
PSVT 0.9846 (n = 27) 1.0000 (n = 0)a
SAV 0.9692 (n = 31) 0.9167 (n = 5)
ST 0.9769 (n = 14) 0.9792 (n = 14)
VPB 0.9923 (n = 6) 0.9375 (n = 16)

Abbreviations for the ECG diagnoses are as in Table 1.

a

The diagnostic class did not appear in the multi-labelling ECGs; thus, the accuracy means the true negative rate.