Skip to main content
. 2022 Nov 9;62(22):5622–5633. doi: 10.1021/acs.jcim.2c01153

Table 2. Performance of Sage and BespokeFit Parameters on the Fragmented Wang Dataset,40 Using the Default QC Chemistry as the Reference Methoda.

force field Max RMSD (Å) RMSE (kcal/mol)
Sage (OpenFF 2.0.0) 0.6520.6100.696 1.0961.0511.144
Sage+BespokeFit 0.6140.5710.658 0.4190.3930.449
Sage+BespokeFit (no restraints) 0.7480.5101.045 0.3510.2620.458
Sage+BespokeFit (no restraints, RMSD) 0.5740.5330.617 0.3490.3270.372
a

The final two rows test details of the parameter optimization procedure (with differences in procedure noted in parentheses), as described in the main text.