Skip to main content
. 2022 Dec 1;65(12):357. doi: 10.1007/s00158-022-03457-w

Table 2.

Distribution of the environmental variables for the building renovation application

Parameter Distribution Parameter 1a Parameter 2b
Room temperature (degree C) Uniform 20 23
Airflow (m3/h,m2) Uniform 0.7 1
Inflation rate (%) Uniform 0.005 0.02
Discount rate (%) Uniform 0.035 0.045
Uncertainty on exterior wall cost (%) Uniform − 20 20
Uncertainty on exterior wall GWPc (%) Uniform − 20 20
Uncertainty on windows cost (%) Uniform − 20 20
Uncertainty on windows GWP (%) Uniform − 20 20
Uncertainty on slab against unheated cost (%) Uniform − 20 20
Uncertainty on slab against unheated GWP (%) Uniform − 20 20
Uncertainty on slab against unheated RSLd (%) Uniform − 20 20
Heating efficiency loss (%) Uniform 15 25
Exterior wall conductivity Gumbel 0.69 0.18
Exterior wall RSL (years) Lognormal 32 2
Windows RSL (years) Lognormal 32 2

aCorresponds to the lower bound for uniform distributions and to the mean for non uniform distributions.

bCorresponds to the upper bound for uniform distributions and to the standard deviation for non uniform distributions.

cGWP stands for global warming potential.

dRSL stands for reference service life