Ahmad 1990.
Study characteristics | ||
Methods | Study characteristics
|
|
Participants | Baseline characteristics
|
|
Interventions | Intervention group
Control group
|
|
Outcomes | Outcomes relevant to this review
|
|
Notes | Funding source: not reported | |
Risk of bias | ||
Bias | Authors' judgement | Support for judgement |
Random sequence generation (selection bias) | Low risk | Quote: "randomized separately at each study center into treatment or control groups using a modified 4 × 4 Latin square. Patients were stratified by sex." |
Allocation concealment (selection bias) | Unclear risk | Insufficient information to permit judgement |
Blinding of participants and personnel (performance bias) | Low risk | Quote: "double‐blind placebo‐controlled" study |
Blinding of outcome assessment (detection bias) Adverse events | Low risk | Quote: "double‐blind placebo‐controlled" study |
Blinding of outcome assessment (detection bias) Muscle symptoms | Low risk | Quote: "double‐blind placebo‐controlled" study |
Blinding of outcome assessment (detection bias) Myocardial function | Low risk | Quote: "double‐blind placebo‐controlled" study |
Incomplete outcome data (attrition bias) Adverse events | Low risk | Quote: "These dropouts occurred for the following reasons: transplantation (2 carnitine, 2 placebo); noncompliance (2 carnitine); patient's request (5 carnitine, 4 placebo). Six of the patients requesting dropout did so during the baseline period (3 from each group)." Missing outcome data balanced in numbers across intervention groups |
Incomplete outcome data (attrition bias) Muscle symptoms | Low risk | Quote: "These dropouts occurred for the following reasons: transplantation (2 carnitine, 2 placebo); noncompliance (2 carnitine); patient's request (5 carnitine, 4 placebo). Six of the patients requesting dropout did so during the baseline period (3 from each group)." Missing outcome data balanced in numbers across intervention groups |
Incomplete outcome data (attrition bias) Myocardial function | Low risk | Quote: "These dropouts occurred for the following reasons: transplantation (2 carnitine, 2 placebo); noncompliance (2 carnitine); patient's request (5 carnitine, 4 placebo). Six of the patients requesting dropout did so during the baseline period (3 from each group)." Missing outcome data balanced in numbers across intervention groups |
Selective reporting (reporting bias) | Unclear risk | The study protocol is not available |
Other bias | Unclear risk | Insufficient information to permit judgement |