Skip to main content
. 2022 Dec 7;12(54):34850–34873. doi: 10.1039/d2ra06734j

Comparison between SCAPS 1D and wxAMPS software simulation.

Device structure Software V OC (V) J SC (mA cm−2) FF (%) PCE (%)
ITO/PCBM/Cs2BiAgI6/CBTS/Au SCAPS-1D 1.08 22.39 82.56 19.99
wxAMPS 1.18 20.86 84.21 20.70
ITO/TiO2/Cs2BiAgI6/CBTS/Au SCAPS-1D 1.08 23.8 83.61 21.55
wxAMPS 1.18 23.00 84.69 23.06
ITO/ZnO/Cs2BiAgI6/CBTS/Au SCAPS-1D 1.085 23.76 83.78 21.59
wxAMPS 1.18 21.97 84.81 22.04
ITO/C60/Cs2BiAgI6/CBTS/Au SCAPS-1D 1.07 19.62 82.65 17.47
wxAMPS 1.18 21.09 84.73 21.03
ITO/IGZO/Cs2BiAgI6/CBTS/Au SCAPS-1D 1.09 23.65 79.04 20.42
wxAMPS 1.19 22.87 82.02 22.38
ITO/SnO2/Cs2BiAgI6/CBTS/Au SCAPS-1D 1.08 23.76 83.54 21.52
wxAMPS 1.18 21.94 82.62 21.93
ITO/CeO2/Cs2BiAgI6/CBTS/Au SCAPS-1D 0.92 23.59 66.21 14.44
wxAMPS
ITO/WS2/Cs2BiAgI6/CBTS/Au SCAPS-1D 1.08 23.53 83.91 21.43
wxAMPS 1.18 21.16 84.94 21.23