1. The following features are diagnostic of left anterior fascicular block on electrocardiogram (ECG):
|
|
|
|
| (a) Left axis deviation |
|
|
|
| (b) qR complexes in leads I and aVL |
|
|
|
| (c) rS complexes in leads II, III and aVF |
|
|
|
| (d) PR interval>200 ms |
|
|
|
|
2. The following features are diagnostic of left bundle branch block on ECG:
|
|
|
|
| (a) QRS duration>120 ms |
|
|
|
| (b) Dominant S wave in lead V6 |
|
|
|
| (c) Absence of Q wave in leads I, V5 and V6 |
|
|
|
| (d) Monomorphic R wave in leads 1, V5 and V6 |
|
|
|
|
3. The following features are diagnostic of right bundle branch block on ECG:
|
|
|
|
| (a) QRS duration>120 ms |
|
|
|
| (b) RSR’ pattern in leads V1 and V2 |
|
|
|
| (c) PR interval>200 ms |
|
|
|
| (d) S wave in leads I, aVL, V5 and V6 |
|
|
|
|
4. The following features are recommended for patient selection for subcutaneous implantable
cardioverter-defibrillator:
|
|
|
|
| (a) Young age |
|
|
|
| (b) Lack of vascular access |
|
|
|
| (c) Need for bradycardia pacing |
|
|
|
| (d) Need for anti-tachycardia pacing |
|
|
|
|
5. The following features are part of Class 1 indications for biventricular implantable cardioverter-defibrillator:
|
|
|
|
| (a) QRS duration≥150 ms |
|
|
|
| (b) Left bundle branch block |
|
|
|
| (c) Left ventricular ejection fraction (LVEF) 40% |
|
|
|
| (d) Atrial fibrillation |
|
|