Table 2.

Mean differences between angular measurement results of parallel (0°) and varying off-z-axis (15° and 45° deviated) double oblique positioning of the femurs on the CT table in the gantry during scanning to test for the independency of femoral positioning.

Femurs: n = 13
Positioning: Three times
CT-scans: 39
Subtraction of the results of different positioning angles Mean p -value
Femoral torsion angle-neck center FTA-NC (0°) - FTA-NC (15°) −0.626 0.075
(FTA-NC) FTA-NC (0°) - FTA-NC (45°) −0.933 0.201
FTA-NC (15°)–FTA-NC (45°) −0.308 0.362
Femoral torsion angle-neck base FTA-NBC (0°)–FTA-NBC (15°) −0.400 0.145
center (FTA-NBC) FTA-NBC (0°)–FTA-NBC (45°) −0.523 0.096
FTA-NBC (15°)–FTA-NBC (45°) −0.123 0.712
Femoral neck inclination angle-neck FIA-NC (0°)–FIA-NC (15°) −0.662 0.124
center (FIA-NC) FIA-NC (0°)–FIA-NC (45°) −0.813 0.170
FIA-NC (15°)–FIA-NC (45°) −0.151 0.644
Femoral neck inclination angle-neck FIA-NBC (0°)–FIA-NBC (15°) 0.659 0.131
base center (FIA-NBC) FIA-NBC (0°)–FIA-NBC (45°) 1.29 0.002
FIA-NBC (15°)–FIA-NBC (45°) 0.628 0.163
Femoral varus or valgus angle FVA-td (0°)–FVA-td (15°) 0.359 0.089
total-distal (FVA-td) FVA-td (0°)–FVA-td (45°) 0.364 0.055
FVA-td (15°)–FVA-td (45°) 0.005 0.966
Femoral varus or valgus angle FVA-pd (0°)–FVA-pd (15°) 0.449 0.015
proximal-distal (FVA-pd) FVA-pd (0°)–FVA-pd (45°) 0.31 0.154
FVA-pd (15°)-FVA-pd (45°) 0.139 0.283