Skip to main content
. 2022 Dec 7;152(6):3294–3312. doi: 10.1121/10.0016365

TABLE II.

Current level mappings. All listeners used a 22-electrode array, where lower values indicate closer proximity to the base of the cochlea. AM depth is expressed relative to the dynamic range, or the CUs between T and M levels. Because some listeners required level adjustments to maintain equal loudness, the final mapping levels were reported. Listener IBF's MAPs were lost when data were moved from the testing computer to the server where data are stored onsite.

Listener ID AM depth (%) Electrode (number) Left ear T level (CU) Left ear M level (CU) Right ear T level (CU) Right ear M level (CU)
IAJ 50 16 99 175 130 213
4 118 184 146 203
IBF 50 16
4
IBK 50 16 135 238 119 229
4 118 221 123 221
IBO 50 16 70 160 65 163
4 70 160 60 140
IBZ 50 16 59 147 109 165
4 60 141 109 169
ICD 50 16 136 190 142 215
4 116 188 122 214
ICI 50 16 92 137 90 145
4 96 136 78 121
ICM 100 16 86 155 54 118
4 73 117 57 126
ICP 100 20 51 157 55 148
8 102 180 112 185
ICS 100 16 90 146 124 181
4 124 177 142 185
IDA 100 16 88 169 97 160
4 79 125 78 113