Nodes and elements of the FE models in the PROFEMUR® Preserve and PROFEMUR® TL stems

Stem position PROFEMUR® Preserve PROFEMUR® TL
Cortical bone Cancellous bone Cortical bone Cancellous bone
Nodes Elements Nodes Elements Nodes Elements Nodes Elements
Neutral 186,556 41,292 81,539 16,890 186,556 41,289 81,539 16,887
Flexion 192,267 42,537 83,633 17,208 192,267 42,534 83,633 17,205
Extension 193,070 42,636 80,841 16,710 193,070 42,633 80,841 16,707
Anteversion 10° 194,341 42,803 82,704 17,092 183,625 40,517 82,704 17,089
Anteversion 40° 188,776 41,916 83,189 17,151 188,776 41,913 83,189 17,148
Valgus 187,531 41,373 81,395 16,848 187,531 41,370 81,395 16,845
Varus 192,173 42,277 83,238 17,151 192,173 42,274 83,238 17,148

The PROFEMUR® Preserve is the short stem and the PROFEMUR® TL is the tapered wedge stem used in this study. PROFEMUR® Preserve and PROFEMUR® TL are manufactured by MicroPort Orthopedics (Arlington, TN, USA)