Skip to main content
. 2022 Nov 25;12(23):4181. doi: 10.3390/nano12234181

Table 1.

Quality control analytical results of [177Lu]Lu−iFAP/iPSMA nanoparticles produced under GMP conditions (results of three batches).

Test Specification Method Results
Activity per vial 3.40 ± 0.20 GBq Ionization chamber 3.45 ± 0.10 GBq
Radioactive
concentration
170 ± 8 MBq/mL Ionization chamber 170 ± 5 MBq/mL
Specific activity ≥0.8 GBq/mg Lu TXRF/
Ionization chamber
0.86 ± 0.4 GBq/mg
Identity of 177Lu Main emission peaks
Eϒ = 113 keV;
208 keV
Gamma
spectrometry
Complies
Radionuclidic purity:
177mLu
Other impurities
≤0.02%
≤0.01%
Gamma
spectrometry
0.009 ± 0.001%
≤0.004%
Chemical purity Co, Ni ≤ 0.1 µg/GBq
Cu, Pb ≤ 0.5 µg/GBq
Fe, Zn ≤ 1.0 µg/GBq
ICP-MS/
Ionization chamber
Ni, Cu < 0.020 µg/GBq
Co < 0.001 µg/GBq
Pb < 0.068 µg/GBq
Zn < 0.074 µg/GBq
Fe < 0.152 µg/GBq
Lutetium content 80–120 mg/L TXRF 102 ± 21 mg/L
pH value 6 ± 1 pH indicator strips 6
Radiochemical purity >98% Ultracentrifugation >99%
Sterility test Sterile Sterility test [32] Sterile
Bacterial endotoxin <20EU/mL Bacterial endotoxin test [32] Complies