Skip to main content
. 2022 Dec 2;18(11):e920–e928. doi: 10.4244/EIJ-D-22-00118

Table 3. Physiologic measurements.

Physiologic measurement Immediately after index procedure Follow-up</p> p-value
Pdrest during wedge 41.1±13.5 20.1±9.7 <0.01
Parest during wedge 95.5±14.1 92±13.6 0.28
Pd/Parest during wedge 0.44±0.13 0.21±0.09 <0.01
Pdhyperaemia during wedge 34.4±11.3 21.5±8.5 <0.01
Pahyperaemia during wedge 90.4±15 92.9±14.8 <0.01
Pd/Pahyperaemia during wedge 0.38±0.11 0.23±0.09 <0.01
FFRcoll during occlusion 0.34±0.11 0.19±0.09 <0.01
(Pw−Pv)/(Pa−Pv) at rest 0.40±0.14 0.17±0.09 <0.01
FFRmyo 0.86±0.11 0.88±0.08 0.06
FFRcor 0.76±0.17 0.84±0.1 <0.01
FFRcoll 0.08±0.11 0.05±0.02 <0.01
Qmax 210±87 255±99 <0.01
Qcor 155±82 215±82 <0.01
Qcoll during occlusion (ml/min) 55±32 38±24 <0.01
Qcoll (ml/min) 14±10 7±5 <0.01
Values represent mean±SD. FFRcoll: fractional flow reserve collateral; FFRcor: fractional flow reserve coronary artery; FFRmyo: fractional flow reserve myocardium; Pa: aortic pressure; Pd: diastolic pressure; Pv: central venous pressure; Pw: wedge pressure. Qcoll during occlusion is the maximal recruitable blood flow over the collateral directly after PCI with an inflated balloon in the just-placed stent. Qcoll is the actual blood flow over the collateral directly after PCI in the open vessel.