Residence time of pollutants in the reactor at different air flow rates with different numbers of applied reactor sections and residence time needed for complete oxidation of 10 ppm of heptane at different air flow rates at RH 6%.

Number of reactor sections Surface of catalyst (cm2) Reaction time of pollutant (s) at different air flow rates
0.5 L min−1 1 L min−1 1.5 L min−1 2 L min−1 2.5 L min−1
1 120 15.6 7.8 5.2 3.9 3.12
2 240 31.2 15.6 10.4 7.8 6.24
3 360 46.8 23.4 15.6 11.7 9.36
4 480 62.4 31.2 20.8 15.6 12.48
5 600 78 39 26 19.5 15.6
Specific reaction time (s cm−2) 0.13 0.065 0.043 0.033 0.026
Reaction time for complete degradation of 10 ppm of heptane (s) 31.2–46.8 23.4–31.2 20.8–26 15.6–19.5 Not achieved