Skip to main content
. Author manuscript; available in PMC: 2024 Mar 1.
Published in final edited form as: Hip Int. 2021 Aug 5;33(2):298–305. doi: 10.1177/11207000211036414

Table 2.

Radiographic measurements of the dysplastic deformity of the matched hip dysplasia patients preoperatively and after PAO. The same radiographic measures were made for the normal hips to ensure that postoperative correction was similar to normal anatomy.

LCEA (degrees) Tönnis Angle (degrees) Extrusion Index
Patient
Pair
Dysplastic Post PAO Normal Dysplastic Post PAO Normal Dysplastic Post PAO Normal
1 12 30 26 22 0 5 0.35 0.17 0.23
2 17 23 25 13 7 7 0.35 0.20 0.24
3 8 36 29 23 8 4 0.41 0.07 0.17
4 21 31 31 8 2 1 0.30 0.16 0.14
5 7 23 25 24 14 10 0.33 0.16 0.22
6 3 23 34 23 3 0 0.40 0.17 0.11
7 18 36 35 17 −4 0 0.27 0.14 0.12
8 15 40 30 12 −5 2 0.29 0.08 0.20
9 7 29 35 20 7 1 0.42 0.19 0.04
10 7 33 36 23 2 0 0.40 0.11 0.05
Median 10 31 31 21 3 2 0.35 0.16 0.15
IQR [7, 16.5] [24.5, 35.3] [26.8, 34.8] [14, 23] [0.5, 7] [0.3, 4.8] [0.31,0.40] [0.12, 0.17] [0.11, 0.22]