Skip to main content
. 2022 Nov 4;10:1801111. doi: 10.1109/JTEHM.2022.3219891

TABLE 4. Comparison of the Classification Results of the True Masses as Benign or Suspicious With Temporal Subtraction (TS) and Temporal Analysis (TA), Using Leave-One-Patient-Out Cross-Validation.

Classifier Sensitivity [%] Specificity [%] Accuracy [%] AUC
LDA TS:
TA:
77.08
73.96
TS:
TA:
76.92
51.92
TS:
TA:
77.03
66.22
TS:
TA:
0.77
0.63
k-NN TS:
TA:
84.38
80.21
TS:
TA:
96.15
55.77
TS:
TA:
88.51
71.62
TS:
TA:
0.90
0.68
SVM TS:
TA:
80.21
90.63
TS:
TA:
98.08
36.54
TS:
TA:
86.49
71.62
TS:
TA:
0.89
0.64
NB TS:
TA:
83.33
83.33
TS:
TA:
65.38
59.62
TS:
TA:
77.03
75.00
TS:
TA:
0.74
0.71
RF TS:
TA:
84.38
77.08
TS:
TA:
82.69
69.23
TS:
TA:
83.78
74.32
TS:
TA:
0.83
0.73
ADA TS:
TA:
87.50
77.08
TS:
TA:
90.38
57.69
TS:
TA:
88.51
70.27
TS:
TA:
0.89
0.67
BAG TS:
TA:
87.50
70.83
TS:
TA:
82.69
57.69
TS:
TA:
85.81
66.22
TS:
TA:
0.85
0.64
GB TS:
TA:
90.63
76.04
TS:
TA:
86.54
55.77
TS:
TA:
89.19
68.92
TS:
TA:
0.89
0.66
Voting TS:
TA:
89.58
79.17
TS:
TA:
94.23
61.54
TS:
TA:
91.22
72.97
TS:
TA:
0.92
0.70
NN TS:
TA:
98.96
93.75
TS:
TA:
96.15
90.38
TS:
TA:
97.97
92.57
TS:
TA:
0.98
0.92