TABLE 5. Comparison of the Sensitivity (SE), Specificity (SP) and Accuracy (AC) of the proposed algorithm with and without the application of SMOTE, for the 5 classifiers with the best performance, using leave-one-patient-out cross-validation.

Classifier normal vs. masses benign vs. suspicious
without SMOTE with SMOTE without SMOTE with SMOTE
k-NN SE:
SP:
AC:
59.46
99.89
99.42
SE:
SP:
AC:
92.57
98.38
98.31
SE:
SP:
AC:
90.63
88.46
89.86
SE:
SP:
AC:
84.38
96.15
88.51
ADA SE:
SP:
AC:
39.86
99.72
99.02
SE:
SP:
AC:
77.03
89.33
89.19
SE:
SP:
AC:
88.54
76.92
84.46
SE:
SP:
AC:
87.50
90.38
85.81
GB SE:
SP:
AC:
75.00
99.95
99.66
SE:
SP:
AC:
89.86
98.69
98.59
SE:
SP:
AC:
93.75
75.00
87.16
SE:
SP:
AC:
90.63
86.54
89.19
Voting SE:
SP:
AC:
65.54
99.99
99.59
SE:
SP:
AC:
90.54
99.51
99.40
SE:
SP:
AC:
92.71
78.85
87.84
SE:
SP:
AC:
89.58
94.23
91.22
NN SE:
SP:
AC:
89.40
99.98
99.85
SE:
SP:
AC:
96.62
99.93
99.89
SE:
SP:
AC:
96.88
94.23
95.95
SE:
SP:
AC:
98.96
96.15
97.97