Skip to main content
. 2022 Nov 28;19(11):822–832. doi: 10.11909/j.issn.1671-5411.2022.11.007

Table 1. Clinical input parameters: short-term and long-term outcomes following SAVR/TAVI.

Parameters Value (range) References
SAVR TAVI
SAVR: surgical aortic valve replacement; TAVI: transcatheter aortic valve implantation.
30-day outcomes
 Mortality 0.0324 (0.0292-0.0356) 0.0307 (0.0276-0.0338) Makkar, et al [36],
Reardon, et al [7],
Adams, et al [21]
 Stroke 0.0321 (0.0289-0.0353) 0.0447 (0.0403-0.0492)
 No complication 0.1083
(0.0975-0.1192)
0.4978 (0.4480-0.5476)
1-year outcomes
 Mortality 0.1108 (0.0997-0.1218) 0.0984 (0.0886-0.1083) Reardon, et al [7],
Adams, et al [21],
Leon, et al [6]
 Stroke 0.0334 (0.0300-0.0367) 0.0253 (0.0228-0.0278)
 Vascular complications 0.0308 (0.0277-0.0339) 0.0554 (0.0498-0.0609)
 Major bleeding 0.3918 (0.3526-0.4309) 0.1626 (0.1463-0.1789)
 Acute kidney injury 0.0495 (0.0446-0.0545) 0.0276 (0.0248-0.0304)
 Atrial fibrillation 0.2489 (0.2240-0.2738) 0.0901 (0.0811-0.0992)
 Pacemaker implantation 0.0595 (0.0535-0.0654) 0.1345 (0.1211-0.1480)
2-year outcomes
 Mortality 0.0744 (0.0669-0.0818) 0.0729 (0.0656-0.0801) Makkar, et al [36],
Reardon, et al [7],
Adams, et al [21]
 Stroke 0.0269 (0.0242-0.0296) 0.0210 (0.0189-0.0231)
 Vascular complications 0.0273 (0.0246-0.0301) 0.0435 (0.0391-0.0478)
 Major bleeding 0.2660 (0.2394-0.2926) 0.0874 (0.0787-0.0962)
 Acute kidney injury 0.0283 (0.0255-0.0311) 0.0180 (0.0162-0.0198)
 Atrial fibrillation 0.1452 (0.1307-0.1597) 0.0570 (0.0513-0.0627)
 Pacemaker implantation 0.0487 (0.0438-0.0539) 0.0581 (0.0523-0.0639)